| Vertical small | Vertical medium size | Vertical large scale | Horizontal small | Horizontal Medium | Horizontal large |
model | I/A type | Type I | I/L type | I-Z/A type | I-Z type | I-Z/L type |
Check the size of the workpiece(mm) | 300x300x300 | 600x600x600 | 800x1200x100 | 300x300x300 | 600x800x300 | 800x1200x300 |
Ray energy | 160kV | 160-50kV | 160-450kV | 160kV | 160-450kV | 160-450kV |
Focus size | glass tube:d=1.0mm(EN12543) |
Metal tube:d=0.4/d=1.0mm(EN12543) |
Plate size | 25x750px/30x750px/40x1000px |
sensitivity | 1-1.5% |
resolving power | >3.0lp/mm |
Translucent thickness | 160kV:Fe20mm/Al100mm(static state) 225kV:Fe30mm/Al150mm(static state) 320kV:Fe55mm/40mm(Static/Dynamic) 450kV:Fe70mm/50mm(Static/Dynamic) |
Load capacity | 10kg | 30kg | 100kg | 10kg | 30kg | 100kg |
Overall weight | 3t | 160kV4t 225kV7t 320kV12t 450kV20t | 160kV4t 225kV7t 320kV12t 450kV20t | 3t | 160kV4t 225kV7t 320kV12t 450kV20t | 160kV4t 225kV7t 320kV12t 450kV20t |
Whole machine power | <3kW | <10kW | <10kW | <3kW | <10kW | <10kW |
Leaky raydose dose
| 160/225kV<1uSv/h 320/450kV<2.5uSv/h, 320/450kVProtective ear chambers are required for dual shielding protection |
Ray path | Horizontal translucency Z-axis vertical lifting Rotate around Z-axis ± 30 ° Small and medium-sized use π - arm detection Large scale adopts a separated structure and servo control to form an inclination angle | Vertical translucency Z-axis vertical lifting Rotate around the horizontal X-axis ± 30 ° (the workpiece moves forward in the X-axis direction) Rotate around the horizontal Y-axis ± 30 ° Optional displacement along the Y-axis Small and medium-sized use C-arm detection Large scale adopts a separated structure and servo control to form an inclination angle |
Workpiece movement |
Optional workpiece rotation Direct/rotary transmission optional Optional manual/robotic loading
|
Optional workpiece rotation Direct/rotary transmission optional Optional manual/robotic loading
|