project | parameter | Remarks |
Radiant pipe diameter range | Φ273mm—Φ710mm |
|
weight | car body | 24Kg | Total weight56.5Kg |
|
Battery (lead-acid) | 32.5Kg | Standard configuration: 2 sets of lead batteries or 1 set of lithium batteries |
X-ray generator | 16Kg |
|
Magnetic locator | 2.8Kg |
|
External dimensions | Spider | 1.18m×0.23m×0.16m | Excluding recycling ring |
X-ray generator | Φ198mm×635mm | XXGHz-2005 (Ceramic Circumferential Cone Target) |
Creep speed | 15m/min~18m/min | |
Turning radius | ≥7D | |
Creepage Distance | 5Km | Round trip |
positioning error | ±5mm | |
Maximum output voltage | 200Kv | 150-200KV continuously adjustable |
Maximum output current | 3mA | |
Maximum penetration thickness | 24mm | A3 steel |
output power | Constant power output | The first (last) film has consistent blackness |
Climbing ability | >35° | Four wheel drive |
Radiation mode | 360°×30° | Circumferential |
Focus size | 1.0×2.3mm | For reference - depending on the type of ray tube |
Battery energy | 120V 、10Ah | lead-acid battery |
Motor power | 250W continuous | Rare earth motor |
exposure time | Touch screen input for 1s~9h continuously adjustable | Chinese subtitle display, touch screen input |
Delay before exposure | 24s | |
Operating temperature range | -40°~ 70° | |
relative humidity | 90% | |
Magnetic locator | Penetration thickness ≥ 34mm | |