YOUR LOCATION:HOME >PRODUCTS
PRODUCTS
PTS series high-frequency X-ray machine
Release date:2023-05-18
Number of views:
Tel:021-64301886
0
  • Details

·Simpler volume for easy integration of the entire machine

· Integrated and digital design, using higher-level AD and DA chips to improve internal signal monitoring, ensuring higher stability and long-term non-stop operation;

· Improve the control accuracy of kV and mA, better than 0.1%, and higher precision can also be customized according to needs;

· Improve the sensitivity of discharge protection and better protect the ray tube and high-voltage circuit。

System Configuration Table

X-ray machine

X-ray tube

High voltage cable

High voltage generator

Control box

cooler

PFS160

-160HP/11

-160HP/20

-160/20

-160/21

-160/22

-160C

N3/160-R24-R24-Xm

PF160C3000

software control

PTCon5000

PFK3000/WA

PFK3000/WC

PFS225

-225HP/11

-225/22

-225FB

-228

P3/250-R24-R24-Xm

PF225C3000

software control

PTCon5000

PFK3000/WA

PFK3000/WC

PFS320

-320HP/11

-320HP/11AX

-320/23

-320/26

-320FB

N3/160-R24-R24-Xm

PF320D6000

software control

PTCon5OOO

PTK4500/OA

PTK4500/OC

PFS450

-451HP/11

-451/26

-450FB

P3/250-R28-R28-Xm

PF450D6000

software control

PTCon5OOO

PTK4500/OA

PTK4500/OC

X-ray machine

Voltage range

Current range

maximum power

Voltage and current accuracy

Voltage and current repetition accuracy

PFS160

10-160kV

0-25mA

3000W

0.25%0.25%

0.01%0.1%

PFS225

10-225kV

0-25mA

3000W

0.25%0.25%

0.01%0.1%

PFS320

10-320kV

0-25mA

4200W

0.25%0.25%

0.01%0.1%

PFS450

10-450kV

0-25mA

4500W

0.25%0.25%

0.01%0.1%

Intelligent control

Touch screen operation, allowing for direct input of parameters and menu selection

Operating language: Chinese/English selectable

Tube type selection: Prefabricated mainstream X-ray tube manufacturer tube type, specific matching can be selected in the system parameter menu for specific X-ray tube models

Power curve: Based on the pre programmed power curve of different X-ray tubes, the characteristics of the tubes can be maximized during use

KV control:

Accuracy: 0.25%; KV step 0.1kV

Stability: After 1 hour of preheating, the change within 8 hours shall not exceed 0.25%

Repetitive accuracy: 0.01%


MA control:

accuracy:0.5%MA step0.1mA

Repetitive accuracy:0.1%

Usage environment

Input power supply: 220V AC ± 10%

Operating temperature: -5 ℃ to 40 ℃

Storage temperature: -25 ℃ to+70 ℃

security

Reserve interlocking protection interface

Real time monitoring of various indicators, automatic fault alarm

Configure the ray work indicator light to flash when the ray is turned on

Cooling liquid flow rate, temperature monitoring and alarm

Translucent thickness


PFS160

PFS225

PFS320

PFS450

Film transparency thickness

34mm

50mm

80mm

108mm

Real time image transmission

20mm

30mm

50mm

60mm

【Film transmission conditions:FFD700mmPb-screen 0.02mm,Blackness2.0,100mAmin;】

【Real time transillumination conditions:FDD=800mmFOD=500mm

Overall characteristics

Strict aging testing is carried out before the entire machine leaves the factory, fully ensuring stability

Anti discharge impact protection, fully improving product reliability and durability

Easy installation, flange connection for high-voltage cables, quick connection for other cables and cooling pipelines

Adopting high-frequency technology has stronger penetration ability and more stable radiation dose


Online inquiry