Portable high-frequency X-ray testing machine
Main performance:
1. Continuous exposure under 300kV/3mA conditions;
2. Wide input voltage range to meet various generator power supply needs;
3. Small size, light weight, strong penetration, and more stable performance;
4. The controller using a three proof box can be used in various harsh environments;
5. Chinese menu and touch screen input for more convenient operation;
6. Adopting PLC program control, with complete protection, automatic training, memory storage and other functions;
Main technical parameters
entry name | D300 directional parameters | Z300 circumferentialparameters |
X-ray generator | weight | 22kg | 22kg |
External dimensions (including end rings) | Φ295×770(D×L) | Φ295×770(D×L) |
controller | weight | 9.6kg | 9.6kg |
External dimensions | Φ264×458(D×L) | Φ264×458(D×L) |
Focus size | 3.0 | 0.8×5(mm) |
Built in filter | 0.4mm steel/nickel/cobalt ± 0.1mm | 0.4mm steel/nickel/cobalt ± 0.1mm |
Radiation angle | 40°×40° | 40°×360° |
Maximum penetration (Fe) | 70mm (A3) / 60mm(A3) | 55mm (A3) / 45mm(A3) |
KV adjustment range | 50 ~300 kV±1kv | 50 ~300 kV±1kv |
MA adjustment range | 0.5 ~3 mA ±0.1mA | 0.5 ~3 mA ±0.1mA |
maximum power | 900W/750W | 900W/750W |
Leakage radiation value | Maximum 5.0msv/h at 1 meter | Maximum 5.0msv/h at 1 meter |
Protection temperature | 80℃ | 80℃ |
Temporary load rate | 100% at an ambient temperature of 20 ℃ | 100% at an ambient temperature of 20 ℃ |
Storage temperature | -25˚C~+70˚C | -25˚C~+70˚C |
supply voltage | AC85~264 V/50~60 Hz | AC85~264 V/50~60 Hz |