System model: XRV225KV
System composition:
Spearman high-voltage generator XRV225 * 1800
XRV controller
High voltage cable, 1 piece, 5 meters, with a complete set of high-voltage generator and X-ray tube flange
Water cooler
X-ray tube Varian HPX225/11
System diagram
Note: The following diagram shows the system diagram for digital and analog control, where IO BOX is an optional component (can be integrated into the detection system control cabinet)


Main technical parameters
1. Spearman high-voltage generator

l KV range 0-225KV increment 0.1kV
l KV accuracy 0.25%
l KV stability: ≤ 0.1% every 8 hours after preheating for 1 hour
l MA range 0-30mA incremental 0.1mA
lMA accuracy 0.25%
l MA stability of 100ppm/° C
l Maximum power 1800W
l Linear adjustment+/-0.005%
l Load adjustment+/-0.05%
l Ripple/noise < 0.025%
l Interface connector digital Ethernet, analog-25 pin connector, RS-232 and USB
l Cooling forced air cooling
l Output connector R28
l Input voltage 180-264vac, single item 47-63HZ
lInput current < 30A/220V AC
l Cathode size 16 "H x 17" W x 31 "D
l Working temperature 0-50 degrees
l Humidity 20% -85% Humidity
2. XRV controller

l Input voltage AC 220V, ± 10%
l Input current 0.5A
l Installation size 133.35mm x 482.6mm x 330.2mm
l Weight 5.44Kg
l Humidity 0% to 95%
l Storage temperature -20 ℃ -+80 ℃
l Working temperature 0 ℃ -+50 ℃
l Digital interface RS232
l Exposure time setting from 0 to 99.9 minutes
l Cooling convection air cooling
l Input power connector 14 pin circular connector
l Training mode selection
l Manual mode selection
l 4 training modes to choose from
l Warning time setting
3. X-ray tube Varian HPX225/11

l Type: Metal ceramic X-ray tube
l Target electrode material: tungsten target
l Focus size: d=0.4mm x 1.0 mm (EN12543 standard)
l Target angle: 11 °
l Radiation angle: 40 ° x 30 °
l Inherent filtration: 0.8mm beryllium
l Maximum power: 1800W
l Maximum tube voltage: 225kV
l Maximum tube current: 8mA@225kV
l Maximum filament current: 4.1A
l Typical filament voltage: 3.0V
l High voltage cable joint: R24
l Cooling flow rate: 4 L/min
l Cooling medium: water cooling
l Weight: 11KG
4. High voltage cable
Model 225KV R24/R28, 5-meter high-voltage cable, 1 piece
5. Cooling system (WL3000S)

l Chiller: water-cooled
l Cooling power: 3000W
l Input voltage 230V+10% -15% 48-62HZ
l Flow 5.4L/ min@4bar
l Cooling liquid capacity 4.0L
l Environmental temperature+5 ° C -+40 ° C
l 10M water pipe, 2 pieces
l 1 power cable
l 1 signal cable
6. IO BOX (optional)



l Main power and auxiliary power control
lCooling power output
l Cooling signal transfer
l Control signal transfer
l Interlocking signal transfer
lWarning light adapter