YOUR LOCATION:HOME >PRODUCTS
PRODUCTS
X-ray digital image detection system for large-diameter welded pipes and containers
Release date:2021-11-08
Number of views:
Tel:021-64301886
0
  • Details

S-series large-diameter welded pipe and container X-ray digital image detection system

The S series inspection system provides customized solutions for quality control of large diameter welded pipes and pressure vessel welds.

Selection Table


Carbon steel/aluminum spiral and straight seam welded pipes


Stainless steel straight seam welded pipe (single wall)

Stainless steel straight seam welded pipe (double wall)

Stainless steel straight seam welded pipe (double wall)

model

S-shaped

S-X type

S-XD/L type

S-XD type

Check the size of the workpiece

Φ219-1220mm L12.5m

Φ 219-1820mm L12.5-18m Φ219-2540mm L12.5m Φ219-3500mm L12.5m

Φ60-1220mm L12.5m

Φ60-1020mm L12m

Φ60-508mm L12m

Ray energy

160/225/320kV

160/225/320kV

225/320/450kV

225/320/450kV

Focus size

Metal tube:d=0.4/d=1.0mm (EN12543)

Plate size

13x325px/15x375px

13x325px/20x500px

13x325px/

20x500px

13x325px/

20x500px

sensitivity

1-1.5%

1-1.5%

1-1.5%

1-1.5%

resolving power

>3.0lp/mm

>3.0lp/mm

>3.0lp/mm

>3.0lp/mm

Translucent thickness

160kV: Fe 14mm/Al 60mm(Single wall)

225kV: Fe 20mm/Al 120mm(Single wall)

320kV: Fe 40mm (Single wall)

450kV: Fe 50mm (Single wall)

225kV: Fe12mm (Double walled)

320kV: Fe 30mm (Double walled)

450kV: Fe 40mm (Double walled)

Load capacity

According to the weight of the workpiece

Whole machine power

<10kW

<10kW

<10kW

<10kW

Leakage dose

<1μSv/h

<1μSv/h

160/225kV<1μSv/h

320/450kV<2.5μSv/h

225kV<1μSv/h

320/450kV<2.5μSv/h

Lead doors for entry and exit

Electric

Electric

Electric

Pneumatic

Ray path

Vertical translucency

Placing the X-ray tube inside the container

Fixed optical path


Vertical translucency

Placing the X-ray tube inside the container

Fixed optical path


Horizontal translucency

Placing the X-ray tube outside the container

Fixed optical path


Vertical translucency

Placing the X-ray tube outside the container

Fixed optical path




Online inquiry